Here you will find drawings, specifications, descriptions and PDF documents for Commercial Wall / Siding Panels from ROC INC.
Looking for something not shown? Ask us.

Ultra-Rib structural exposed fastener roof and wall system.
• 26 gauge industrial quality steel or AZ50 (painted) and AZ50 (unpainted) coatings
• Full 36" coverage
• Purlin bearing leg
• Minimum roof pitch 1:12
• All orders custom cut to lengths up to 40'
• Perfect for commercial and industrial applications
• Aluminum available on an inquiry basis

Ultra-Rib structural exposed fastener roof and wall system.
• 26 gauge industrial quality steel or AZ50 (painted) and AZ50 (unpainted) coatings
• Full 36" coverage
• Purlin bearing leg
• Minimum roof pitch 1:12
• All orders custom cut to lengths up to 40'
• Perfect for commercial and industrial applications
• Aluminum available on an inquiry basis

An industry standard—Ideal for heavy industrial and lagging applications.
• Available mill finish, clad or painted in .032", .040" and .050" aluminum • Available in 24, 22 & 20 gauge steel, 32" coverage
• Panels can be curved
• Minimum slope for steel roofing applications is 21/2:12
• Standard lengths: 6'-45'
• 8" Rib available on an inquiry basis
• The allowable loads are based on 1986 AISI and 1986 Aluminum Association specifications.
• The allowable loads are based on stress only.
• The allowable loads for the steel load table may be increased by 1/3 for wind loading. The allowable loads have been increased for the aluminum load tables by 1/3 for wind loading. • The use of steel 4" Rib panels on roof pitches less than 2 1/2":12 (12°) is not recommended.
• The maximum individual panel length for steel 4" Rib on roofs in 32' due to thermal movement considerations.
• The use of aluminum 4" Rib panels on roofs is not recommended.

The Deep Rib II panel shall have a coverage of 30" for steel and 40" for aluminum". Rib height shall be 2". Panels shall be directly fastened to the substrate. The panel shall have a overlapping sidelap feature.
• Can be used for both wall and roof applications
• Available in 22 and 18 gauge steel
• Available in .032", .040" and .050" aluminum (43-7/8" panel with 40" coverage)

A bold rib design, perfect for horizontal and vertical applications. Large 4" deep ribs provide excellent strength and spanning capacity. Can be used inverted for roof applications. Minimum roof slope: 1:12. Excellent for applications with large spans between structural framing members. Standard lengths: 6'-45'
• The Deep Rib IV panel shall have a coverage of 24". Rib height shall be 4".
• Panels shall be directly fastened to the substrate.
• The panel shall have a overlapping sidelap feature.

A classic design with 7.2" rib spacing. Excellent strength and spanning capability. Excellent for both wall and roof applications.
• Available in .032" and .040" aluminum
• Available in 24, 22, 20 and 18 gauge steel
• Panels can be curved
• Minimum slope for roofing applications is 2:12
• Standard lengths: 6'-45' • 36" wide weather coverage
• Diaphragm capacity per ICBO Evaluation Report

• Classic mechanical seamed trapezoidal panel design
• Designed for low slope industrial applications
• Ideal for high performance Pre-Engineered Metal Buildings
• 3" nominal seam height - 24" seam centers
• 180 and 360 degree seaming available
• Factory applied sealant standard
• Concealed clip allows for thermal movement
• Normally installed over open framed structures

• Classic engineered snap-together trapezoidal panel design
• Designed for low slope industrial applications
• Ideal for Pre-Engineered Metal Buildings and Mini Storage Structures
• 3" nominal seam height - 24" seam centers
• Factory applied sealant standard
• Concealed clip allows for thermal movement
• Normally installed over open framed structures

The Mighti-Rib PBR panel shall have a coverage of 36". Panels shall be directly fastened to the substrate. The panel shall have an overlapping sidelap feature.
• Excellent for commercial and industrial applications
• 26 gauge full hard (80 ksi) steel
• Diaphragm capacity per ICBO Evaluation Report
• Standard lengths: 6'-45'
• PBR panels require a minimum slope of 1:12
• UL90 rating for PBR panels when attached to steel purlins
• Available unpainted or finished with high-performance Super Alurite® paint system

The V-Beam panel shall have a coverage of 32" for steel and 42 aluminum. Rib height shall be 1¾". Panels shall be directly fastened to the substrate. The panel shall have a overlapping sidelap feature.
• Minimum slope for roofing applications is 2:12
• Available in .040" and .050" aluminum
• Excellent strength and spanning capability
• Diaphragm capacity per ICBO Evaluation Report
• Standard lengths: 6'-45'

The Select Series panels shall have one 6" wide raised rib and 6" wide flush rib for a total coverage of 12". The raised rib shall have a depth of 1 7/16". There shall be one small stiffening bead centered in each rib. The panels shall have an interlocking sidelap feature which hides the fasteners. Panels shall be attached to the substrate with concealed fasteners.
• Concealed fasteners for maximum aesthetic value • 2 stiffening ribs standard • Perfect for walls, fascias and equipment screens • Panel ends can be swedged and endlapped • Available with factory-applied sealant to ensure a weathertight wall assembly • Standard lengths: 6'-45'

Factory formed, prefinished, lappable, exposed fastener, structural ribbed metal roof and wall system, that has been pretested and certified by manufacturer to comply with specified requirements under installed conditions.